products

TECHNOFLOOR STANDARD - 1200 * 600 * 30 mm (5.76 sq / m)
TECHNOFLOOR STANDARD - 1200 * 600 * 30 mm (5.76 sq / m)
TECHNOFLOOR STANDARD - 1200 * 600 * 30 mm (5.76 sq / m)
# 01008

TECHNOFLOOR STANDARD - 1200 * 600 * 30 mm (5.76 sq / m)

TECHNOFLOOR STANDARD - Non-flammable slabs made of stone wool. Slabs are designed for thermal and sound insulation layers in the systems of sound insu... See more

TECHNOFLOOR STANDARD - Non-flammable slabs made of stone wool. Slabs are designed for thermal and sound insulation layers in the systems of sound insulation for buildings.

See less

Delivery time: 3-5 working days

Parameter name

Measurement unit

Criteria

Value

Test Methodology

Thermal conductivity, λ10

W/m·°K

Not above

0,036

State All-Union standard 7076-99, State All-Union standard 31925, State All-Union standard 31924

Thermal conductivity, λD

W/m·°K

Not above

0,037

State All-Union standard EN 32314

Thermal conductivity, λА

W/m·°K

Not above

0,039

State All-Union standard 7076-99, Code of Practice 23-101-2004

Thermal conductivity, λБ

W/m·°K

Not above

0,041

State All-Union standard 7076-99, Code of Practice 23-101-2004

Compressive strength at 10 % of deformation

kPa

Not less than

25

State All-Union standard EN 826-2011

Organic matter contents

%

Not above

4,5

State All-Union standard 17177-94

Short-run water absorption at partial immersion

kg/m2

Not above

1

State All-Union standard EN 1609-2011

Water absorption at partial immersion of samples during fixed long-time

kg/m2

Not above

3

State All-Union standard EN 12087

flammability

degree

-

non-flammable

State All-Union standard 30244-94

Density

kg/m3

-

110 (±10)

State All-Union standard 17177-94

 

Parameter name

Measurement unit

Criteria

Value

length

mm

1200 (1000)*

State All-Union standard EN 822

Width

mm

600

State All-Union standard EN 822

Thickness

mm

20-50*

State All-Union standard EN 823

Grade by thickness

Т

Т4

State All-Union standard 32314-2015.

 

  • High durability
  • Use of 30 mm thick TECHNOFLOOR STANDARD in the structure of floating floor with sand cement screed reduces the impact noise level by half* than the same structure without TECHNOFLOOR STANDARD slabs
  • Fast application
  • Guarantees safety and environmental performance
  • Slabs are used in industrial and civil construction as:
  • a thermal and sound insulation layer in floating floors with sheet-backing coat screed
  • a thermal and sound insulation layer in floating floors when concrete or cement screed is applied directly to thermal insulation layer
  • Storage: 
  • Slabs must be stored into containers or stacked on the pallets separately by trade mark and size. Polyethylene heat-shrink film is used for packaging. The material must be protected from atmospheric precipitation during whole period of storage.
  • Transportation: 
  • Transportation and storage of the slabs must be in compliance with State All-Union standard 25880-83. 