Electric wire H05VVH2-U 3X2.5 (dry)
- category: Wires
Flat rigid copper cable with polyvinyl chloride insulation.
Flat rigid copper cable with polyvinyl chloride insulation.
See less
- Specifications
- Application area
- Minimum bending radius: 4xD 5xD 6xD
- Maximum operating temperature: 60°
- Maximum short circuit temperature: 150°
- Rated voltage: 300/300 V-300/500 V
- Test voltage: 2 kV
- Permissible continuous core temperature during operation: EN 60332-1
Number of conductors and nominal cross-section
Cable outer diameter
Weight of 1 km of cable
Electrical resistance of the core at 20°C
Not more than the permissible current load in air
mm2 mm mm kg ohm/km ampere
3 x 2.5 5.8 x 12.9 158 7.98 25
Used in dry and humid environments where the risk of mechanical damage is
low. Mainly used for household appliances.
Products offered
delivery
- When purchasing products for up to 100 GEL, the delivery price is 6 GEL;
- When purchasing products in the amount of 100 to 500 GEL, the delivery price is determined on the basis of: 1 km - 1.50 GEL;
- When purchasing products worth more than GEL 300, delivery is free (Tbilisi);
- The cost of delivery outside the city is determined at the rate: 1 km - 2 GEL.
Delivery time:
- Tbilisi | Rustavi | Mtskheta | Kutaisi | Batumi
Delivery time: 3-5 working days
- Out of town:
Delivery time: 4-5 working days
Note: Delivery is carried out only to the address, without unloading from the car and delivery to the apartment.
Product comparison

Electric wire H05VVH2-U 3X2.5 (dry)
choose a product
- HO5VVH2-U
- Electric wire H05VVH2-F 3 X 4,00 mm² (multi-tip)
- ელ. სადენი H05VVH2-F 2X1.5
- Electric wire H05VVH2-U 2 X 1,50 mm² (single tip)
- ელ. სადენი H05VVH2-U 2X2.5
- HO5VVH2-F
- ელ. სადენი H05VVH2-U 3X4
- Electric wire H05VVH2-U 3 X 1,50 mm² (single tip)
- HO5VVH2-U
- UNALKABLO Unitech ® CAT 5 e F-UTP 4 X 2 X 24 AWG
- Electric cable H05VVH2-F 3X2.5 (multi-core)
- ელ. სადენი YAVV (NAYY) 2X10 (ალუმინის კაბელი)
- Electric wire H05VVH2-U 3 X 2,50 mm² (single tip)
- Electric wire H05VVH2-U 2 X 4,00 mm² (single tip)
- Electric wire H05VVH2-F 2 X 1,50 mm² (multi-tip)
- Minimum bending radius: 4xD 5xD 6xD
- Maximum operating temperature: 60°
- Maximum short circuit temperature: 150°
- Rated voltage: 300/300 V-300/500 V
- Test voltage: 2 kV
- Permissible continuous core temperature during operation: EN 60332-1
Number of conductors and nominal cross-section
Cable outer diameter
Weight of 1 km of cable
Electrical resistance of the core at 20°C
Not more than the permissible current load in air
mm2 mm mm kg ohm/km ampere
3 x 2.5 5.8 x 12.9 158 7.98 25