TECHNOFLOOR STANDARD - 1200 * 600 * 30 mm (5.76 sq / m)
- category: ქვაბამბა / ხმის იზოლაცია
- Brands: TECHNONICOL
TECHNOFLOOR STANDARD - Non-flammable slabs made of stone wool. Slabs are designed for thermal and sound insulation layers in the systems of sound insu... See more
TECHNOFLOOR STANDARD - Non-flammable slabs made of stone wool. Slabs are designed for thermal and sound insulation layers in the systems of sound insulation for buildings.
See less
Parameter name |
Measurement unit |
Criteria |
Value |
Test Methodology |
Thermal conductivity, λ10 |
W/m·°K |
Not above |
0,036 |
State All-Union standard 7076-99, State All-Union standard 31925, State All-Union standard 31924 |
Thermal conductivity, λD |
W/m·°K |
Not above |
0,037 |
State All-Union standard EN 32314 |
Thermal conductivity, λА |
W/m·°K |
Not above |
0,039 |
State All-Union standard 7076-99, Code of Practice 23-101-2004 |
Thermal conductivity, λБ |
W/m·°K |
Not above |
0,041 |
State All-Union standard 7076-99, Code of Practice 23-101-2004 |
Compressive strength at 10 % of deformation |
kPa |
Not less than |
25 |
State All-Union standard EN 826-2011 |
Organic matter contents |
% |
Not above |
4,5 |
State All-Union standard 17177-94 |
Short-run water absorption at partial immersion |
kg/m2 |
Not above |
1 |
State All-Union standard EN 1609-2011 |
Water absorption at partial immersion of samples during fixed long-time |
kg/m2 |
Not above |
3 |
State All-Union standard EN 12087 |
flammability |
degree |
- |
non-flammable |
State All-Union standard 30244-94 |
Density |
kg/m3 |
- |
110 (±10) |
State All-Union standard 17177-94 |
Parameter name |
Measurement unit |
Criteria |
Value |
length |
mm |
1200 (1000)* |
State All-Union standard EN 822 |
Width |
mm |
600 |
State All-Union standard EN 822 |
Thickness |
mm |
20-50* |
State All-Union standard EN 823 |
Grade by thickness |
Т |
Т4 |
State All-Union standard 32314-2015. |
- High durability
- Use of 30 mm thick TECHNOFLOOR STANDARD in the structure of floating floor with sand cement screed reduces the impact noise level by half* than the same structure without TECHNOFLOOR STANDARD slabs
- Fast application
- Guarantees safety and environmental performance
- Slabs are used in industrial and civil construction as:
- a thermal and sound insulation layer in floating floors with sheet-backing coat screed
- a thermal and sound insulation layer in floating floors when concrete or cement screed is applied directly to thermal insulation layer
- Storage:
- Slabs must be stored into containers or stacked on the pallets separately by trade mark and size. Polyethylene heat-shrink film is used for packaging. The material must be protected from atmospheric precipitation during whole period of storage.
- Transportation:
- Transportation and storage of the slabs must be in compliance with State All-Union standard 25880-83.
Products offered
delivery
- When purchasing products for up to 100 GEL, the delivery price is 6 GEL;
- When purchasing products in the amount of 100 to 500 GEL, the delivery price is determined on the basis of: 1 km - 1.50 GEL;
- When purchasing products worth more than GEL 300, delivery is free (Tbilisi);
- The cost of delivery outside the city is determined at the rate: 1 km - 2 GEL.
Delivery time:
- Tbilisi | Rustavi | Mtskheta | Kutaisi | Batumi
Delivery time: 3-5 working days
- Out of town:
Delivery time: 4-5 working days
Note: Delivery is carried out only to the address, without unloading from the car and delivery to the apartment.
Product comparison
TECHNOFLOOR STANDARD - 1200 * 600 * 30 mm (5.76 sq / m)
choose a product
- Length, width 1200 mm, thickness 600 mm, area 20 mm, quantity 0.72 m2 in a package of 15 pcs.
- ქვაბამბა TECHNOFAC OPTIMA 1200*600*100 მმ (2.16 კვ/მ)
- Stone wool - Ravatherm 40 kg/m3 100x600x1200 mm (2.88 m2)
- Terrawool 50მმ 600x1200 40 კგ/მ3 5.76 მ2
- Terrawool 100kg/m3 x 50mm 600x1200 2.88 მ2
- SCANDIC - 800 * 600 * 100 mm -2.88 sq / m
- Terrawool 100მმ 600x1200 40 კგ/მ3 2.88 მ2
- TechnoSonus Hydro
- R-COMPOSIT 10 KG
- TechnoSonus VEM 4 SA
- TechnoSonus VEM 2 SA
- TechnoSonus VEM 4
- Sonoplat Standard
- Membrane FLEX AL SA
- Soundproof plasterboard tile AcousticGyps (2000mm*1200mm*12.5mm) 2.4m2
Parameter name |
Measurement unit |
Criteria |
Value |
Test Methodology |
Thermal conductivity, λ10 |
W/m·°K |
Not above |
0,036 |
State All-Union standard 7076-99, State All-Union standard 31925, State All-Union standard 31924 |
Thermal conductivity, λD |
W/m·°K |
Not above |
0,037 |
State All-Union standard EN 32314 |
Thermal conductivity, λА |
W/m·°K |
Not above |
0,039 |
State All-Union standard 7076-99, Code of Practice 23-101-2004 |
Thermal conductivity, λБ |
W/m·°K |
Not above |
0,041 |
State All-Union standard 7076-99, Code of Practice 23-101-2004 |
Compressive strength at 10 % of deformation |
kPa |
Not less than |
25 |
State All-Union standard EN 826-2011 |
Organic matter contents |
% |
Not above |
4,5 |
State All-Union standard 17177-94 |
Short-run water absorption at partial immersion |
kg/m2 |
Not above |
1 |
State All-Union standard EN 1609-2011 |
Water absorption at partial immersion of samples during fixed long-time |
kg/m2 |
Not above |
3 |
State All-Union standard EN 12087 |
flammability |
degree |
- |
non-flammable |
State All-Union standard 30244-94 |
Density |
kg/m3 |
- |
110 (±10) |
State All-Union standard 17177-94 |
Parameter name |
Measurement unit |
Criteria |
Value |
length |
mm |
1200 (1000)* |
State All-Union standard EN 822 |
Width |
mm |
600 |
State All-Union standard EN 822 |
Thickness |
mm |
20-50* |
State All-Union standard EN 823 |
Grade by thickness |
Т |
Т4 |
State All-Union standard 32314-2015. |