TECHNOACOUSTIC is a nonflammable, water-repellent thermal and sound insulation slabs made of mineral wool based on lowphenolic-bound basalt rocks. The particular position of its fibers provide high sound-absorbing properties. Acoustic mineral wool has high physical and mechanical parameters providing reliable performance of the product in vertical structures.
See less
Parameter name |
Measurement unit |
Criteria |
Value |
Test Methodology |
Thermal conductivity, λ10 |
W/m·°K |
Not above |
0,035 |
State All-Union standard 7076-99, State All-Union standard 31925-2011 (EN 12667:2001), State All-Union standard31924-2011 (EN 12939:2000) |
Thermal conductivity, λD |
W/m·°K |
Not above |
0,036 |
State All-Union standard 32314-2011 (EN 13162:2008) |
Thermal conductivity, λА |
W/m·°K |
Not above |
0,038 |
State All-Union standard 7076-99, СП 23-101-2004 |
Thermal conductivity, λБ |
W/m·°K |
Not above |
0,039 |
State All-Union standard 7076-99, СП 23-101-2004 |
Compressive strength at 10 % of deformation |
kPa |
Not above |
0,5 |
State All-Union standard EN 826-2011 |
Organic matter contents |
% |
Not above |
2,5 |
State All-Union standard 17177-94 |
Short-run water absorption at partial immersion |
kg/m2 |
Not above |
1 |
State All-Union standardEN 1609-2011 |
Water absorption at partial immersion of samples during fixed long-time |
kg/m2 |
Not above |
3 |
State All-Union standard EN 12087-2011 |
flammability |
degree |
- |
non-flammable |
State All-Union standard 30244-94 |
Плотность |
kg/m3 |
- |
41 (±4) |
State All-Union standard 17177-94 |
Parameter name |
Measurement unit |
Criteria |
Value |
length |
mm |
1200 (1000)* |
State All-Union standard EN 822-2011 |
Width |
mm |
50; 75; 100 |
State All-Union standard EN 822-2011 |
Thickness |
mm |
20-50* |
State All-Union standard EN 823-2011 |
Grade by thickness |
Т |
Т4 |
State All-Union standard 32314-2011 (EN 13162:2008) |
- diminishes five-fold airborne noise level when used within the system “TH-Stena Acoustic” with 100 mm thick TECHNOACOUSTIC slabs.
- doesn’t shrink
- guarantees safety and environmental performance
- Slabs are used in industrial and civil construction as:
- a thermal and sound insulation layer not being under load: light-weight covering surfaces, partition walls, floors, crawl space slabs, attics and lofts, garret flooring;
- a sound insulation layer in suspended ceilings.
- Storage: Slabs must be stored into containers or stacked on the pallets separately by trade mark and size. Polyethylene heat-shrink film is used for packaging. The material must be protected from atmospheric precipitation during whole period of storage.
- Transportation: Transportation and storage of the slabs must be in compliance with State All-Union standard 25880-83. The slabs are unloaded at storage at least a day before delivering to a customer.
Products offered
delivery
- When purchasing products for up to 100 GEL, the delivery price is 6 GEL;
- When purchasing products in the amount of 100 to 500 GEL, the delivery price is determined on the basis of: 1 km - 1.50 GEL;
- When purchasing products worth more than GEL 300, delivery is free (Tbilisi);
- The cost of delivery outside the city is determined at the rate: 1 km - 2 GEL.
Delivery time:
- Tbilisi | Rustavi | Mtskheta | Kutaisi | Batumi
Delivery time: 3-5 working days
- Out of town:
Delivery time: 4-5 working days
Note: Delivery is carried out only to the address, without unloading from the car and delivery to the apartment.
Product comparison
TECHNOACOUSTIC - 1200 * 600 * 50 mm (5.76 sq / m)
choose a product
- Terrawool 50მმ 600x1200 40 კგ/მ3 5.76 მ2
- ქვაბამბა TERRAWOOL 50mm 600x1200(130კგ/მ3) 2.88 მ2
- Stone wool - Ravatherm 40 kg/m3 100x600x1200 mm (2.88 m2)
- Rolled stone wool with wire mesh Isotec Wired Mat 80 SM 2000x1000x50 mm. (2 sq.m.)
- Stone wool ISOBOX 800*600*50 15 panels/pack (7.2 m2)
- Rolled stone wool with wire mesh Isotec Wired Mat 40 SM 4000x1000x50 mm. (4 sq.m.)
- SCANDIC - 800 * 600 * 50 mm-5.76 sq / m
- Length, width 1200 mm, thickness 600 mm, area 20 mm, quantity 0.72 m2 in a package of 15 pcs.
- Stone wool - Ravatherm 120 kg/m3 100x600x1200 mm (1.44 m2)
- Stone wool - Ravatherm 110 kg/m3 50x600x1200 mm (2.88 m2)
- Rolled stone wool with wire mesh Isotec Wired Mat 100 SM 2000x1000x50 mm. (2 sq.m.)
- Mapesonic CR 4mm x 1mt rolls 10 mt
- Acoustic casing SoundPack M
- Sonoplat Combi
- Vibroflor (15m*1m*4mm) 15 m2
Parameter name |
Measurement unit |
Criteria |
Value |
Test Methodology |
Thermal conductivity, λ10 |
W/m·°K |
Not above |
0,035 |
State All-Union standard 7076-99, State All-Union standard 31925-2011 (EN 12667:2001), State All-Union standard31924-2011 (EN 12939:2000) |
Thermal conductivity, λD |
W/m·°K |
Not above |
0,036 |
State All-Union standard 32314-2011 (EN 13162:2008) |
Thermal conductivity, λА |
W/m·°K |
Not above |
0,038 |
State All-Union standard 7076-99, СП 23-101-2004 |
Thermal conductivity, λБ |
W/m·°K |
Not above |
0,039 |
State All-Union standard 7076-99, СП 23-101-2004 |
Compressive strength at 10 % of deformation |
kPa |
Not above |
0,5 |
State All-Union standard EN 826-2011 |
Organic matter contents |
% |
Not above |
2,5 |
State All-Union standard 17177-94 |
Short-run water absorption at partial immersion |
kg/m2 |
Not above |
1 |
State All-Union standardEN 1609-2011 |
Water absorption at partial immersion of samples during fixed long-time |
kg/m2 |
Not above |
3 |
State All-Union standard EN 12087-2011 |
flammability |
degree |
- |
non-flammable |
State All-Union standard 30244-94 |
Плотность |
kg/m3 |
- |
41 (±4) |
State All-Union standard 17177-94 |
Parameter name |
Measurement unit |
Criteria |
Value |
length |
mm |
1200 (1000)* |
State All-Union standard EN 822-2011 |
Width |
mm |
50; 75; 100 |
State All-Union standard EN 822-2011 |
Thickness |
mm |
20-50* |
State All-Union standard EN 823-2011 |
Grade by thickness |
Т |
Т4 |
State All-Union standard 32314-2011 (EN 13162:2008) |