TECHNOFAC OPTIMA 1200 * 600 * 50 mm (4.32 sq / m)
- category: ქვაბამბა
- Brands: TECHNONICOL
The product description:TECHNOPHAS OPTIMA is a nonflammable, water-repellent thermal and sound insulation slabs made of mineral wool based on lowpheno... See more
The product description:
TECHNOPHAS OPTIMA is a nonflammable, water-repellent thermal and sound insulation slabs made of mineral wool based on lowphenolic-bound basalt rocks.
Organizational Standard 72746455-3.2.6-2018
See less
Parameter name |
Measurement unit |
Criteria |
Value |
Test Methodology |
Thermal conductivity, λ10 |
W/m·°K |
Not above |
0,036 |
State All-Union standard7076-99, State All-Union standard31925-2011 (EN 12667:2001), State All-Union standard 31924-2011 (EN 12939:2000) |
Thermal conductivity, λD |
W/m·°K |
Not above |
0,037 |
State All-Union standard 32314-2011 (EN 13162:2008) |
Thermal conductivity, λА |
W/m·°K |
Not above |
0,040 |
State All-Union standard7076-99, Code of Practice 23-101-2004 |
Thermal conductivity, λБ |
W/m·°K |
Not above |
0,041 |
State All-Union standard 7076-99, Code of Practice 23-101-2004 |
Compressive strength at 10 % of deformation |
kPa |
Notless than |
30 |
State All-Union standard EN 826-2011 |
Tensile strength perpendicular to outer surfaces |
kPa |
Notless than |
15 |
State All-Union standard EN 1607-2011 |
Organic matter contents |
% |
Not above |
4,5 |
State All-Union standard 17177-94 |
Short-run water absorption at partial immersion |
kg/m2 |
Not above |
1 |
State All-Union standard EN 1609-2011 |
Water absorption at partial immersion of samples during fixed long-time |
kg/m2 |
Not above |
3 |
State All-Union standard EN 12087-2011 |
Flammability |
degree |
- |
non-flammable |
State All-Union standard 30244-94 |
Density |
kg/m3 |
- |
120 (±10) |
State All-Union standard 17177-94 |
Parameter name |
Measurement unit |
Criteria |
Value |
length |
mm |
1200 (1000)* |
State All-Union standardEN 822-2011 |
Width |
mm |
600 |
State All-Union standardEN 822-2011 |
Thickness |
mm |
40-250* |
State All-Union standardEN 823-2011 |
Grade by thickness |
Т |
Т4 |
State All-Union standard32314-2011 (EN 13162:2008) |
TECHNOPHAS OPTIMA slabs are used TECHNOPHAS STANDARD LIGHT slabs are used in industrial and civil construction as a thermal and sound insulating layer in exterior thermal insulation systems with a thin protective and decorative plaster layer (with no height limitation).
Work Performance:
Based on organization standard 72746455-4.4.1-2016 «Facade Systems of Building Outdoor Insulation».
Storage:
Slabs must be stored into containers or stacked on the pallets separately by trade mark and size. The material must be protected from atmospheric precipitation during whole period of storage.
Transportation:
Transportation and storage of the slabs must be in compliance with State All-Union standard 25880-83. The slabs are unloaded at storage at least a day before delivering to a customer.
Packaging data:
Polyethylene heat-shrink film is used for packaging. The methodology for wrapping and fixation of the packaging material must ensure safe and reliable packaging of slabs, their safe-keeping and integrity at load-unload works, transporting and storage.
Products offered
delivery
- When purchasing products for up to 100 GEL, the delivery price is 6 GEL;
- When purchasing products in the amount of 100 to 500 GEL, the delivery price is determined on the basis of: 1 km - 1.50 GEL;
- When purchasing products worth more than GEL 300, delivery is free (Tbilisi);
- The cost of delivery outside the city is determined at the rate: 1 km - 2 GEL.
Delivery time:
- Tbilisi | Rustavi | Mtskheta | Kutaisi | Batumi
Delivery time: 3-5 working days
- Out of town:
Delivery time: 4-5 working days
Note: Delivery is carried out only to the address, without unloading from the car and delivery to the apartment.
Product comparison
TECHNOFAC OPTIMA 1200 * 600 * 50 mm (4.32 sq / m)
choose a product
- Stone wool - Ravatherm 145 kg/m3 30x600x1200 mm (5.76 m2)
- ქვაბამბა Terrawool 145kg/m3 x 30mm 600x1200
- Stone wool - Ravatherm 135 kg/m3 50x600x1200 mm (2.88 m2)
- ქვაბამბა TERRAWOOL 30X600X1200 (120კგ/მ3) 5.76 მ2
- ქვაბამბა Terrawool 70kg/m3 x 100mm 600x1200
- ქვაბამბა TERRAWOOL TW12040 40X600X1200 (120კგ/მ3)
- ISOVER Sound Insulation
- Rolled stone wool with wire mesh and foil Isotec Wired Mat 100 SM AL 2000x1000x50 mm. (2 sq.m.)
- Rockfacad - 1000 * 600 * 50 mm 2.4 sq / m
- ISOVER ვენტი ოპტიმალ
- ქვაბამბა BONUSWOOL PREMIUM F FACADE 1200*600*50 120 kg/m3 (3,60m2)
- Rolled stone wool with wire mesh Isotec Wired Mat 80 SM 2000x1000x50 mm. (2 sq.m.)
- Soundproofing Stone wool StopZvuk Eco Slim
- Stone wool STARROCK 40kg/m3 1200*600*50 (5.76m2)
- ქვაბამბა TERRAWOOL TW12040 50X600X1200 (120კგ/მ3)
Parameter name |
Measurement unit |
Criteria |
Value |
Test Methodology |
Thermal conductivity, λ10 |
W/m·°K |
Not above |
0,036 |
State All-Union standard7076-99, State All-Union standard31925-2011 (EN 12667:2001), State All-Union standard 31924-2011 (EN 12939:2000) |
Thermal conductivity, λD |
W/m·°K |
Not above |
0,037 |
State All-Union standard 32314-2011 (EN 13162:2008) |
Thermal conductivity, λА |
W/m·°K |
Not above |
0,040 |
State All-Union standard7076-99, Code of Practice 23-101-2004 |
Thermal conductivity, λБ |
W/m·°K |
Not above |
0,041 |
State All-Union standard 7076-99, Code of Practice 23-101-2004 |
Compressive strength at 10 % of deformation |
kPa |
Notless than |
30 |
State All-Union standard EN 826-2011 |
Tensile strength perpendicular to outer surfaces |
kPa |
Notless than |
15 |
State All-Union standard EN 1607-2011 |
Organic matter contents |
% |
Not above |
4,5 |
State All-Union standard 17177-94 |
Short-run water absorption at partial immersion |
kg/m2 |
Not above |
1 |
State All-Union standard EN 1609-2011 |
Water absorption at partial immersion of samples during fixed long-time |
kg/m2 |
Not above |
3 |
State All-Union standard EN 12087-2011 |
Flammability |
degree |
- |
non-flammable |
State All-Union standard 30244-94 |
Density |
kg/m3 |
- |
120 (±10) |
State All-Union standard 17177-94 |
Parameter name |
Measurement unit |
Criteria |
Value |
length |
mm |
1200 (1000)* |
State All-Union standardEN 822-2011 |
Width |
mm |
600 |
State All-Union standardEN 822-2011 |
Thickness |
mm |
40-250* |
State All-Union standardEN 823-2011 |
Grade by thickness |
Т |
Т4 |
State All-Union standard32314-2011 (EN 13162:2008) |